{"finding":{"findingId":"01a10ab8-fc65-7029-b571-747e83a46ee4","status":"false_positive","tier":2,"rule":{"name":"flaring","version":"1.0","params":{"clusterKm":1,"days":30,"minFrp":5,"minNights":5,"revisitHours":18}},"title":"Persistent flaring near Eleme, Rivers (Nigeria): 1 cluster(s), up to 6 nights","summary":"1 VIIRS night-time heat cluster(s) with FRP ≥ 5 MW persisted on ≥ 5 of the last 30 nights; the most persistent was lit 6 nights (max 9.88 MW). 1 sit on known VNF 2024 flare sites.","geometry":{"type":"Point","coordinates":[7.044,4.551]},"bbox":[6.86,4.43,7.35,5.11],"aoi":{"id":"flare-nga-4p9n-7p1e","name":"Flare field near Eleme, Rivers (Nigeria) — 20 registered sites","tags":["flaring","oil-gas","discovered","nga","nga_ups_7.1197e_4.8933n"]},"context":{"enso":{"phase":"El Niño","oni":2.16},"events":[]},"blindSpots":["Cannot tell a gas flare from an industrial furnace, refinery, steel or cement kiln, or a volcano — only persistence and the VNF site match argue 'flare'.","Cloud and heavy smoke hide nights; a cloudy month under-counts persistence and can look like a flare was turned off.","FRP is not flared volume: the VIIRS I-band saturates on the largest flares and the FIRMS FRP is a single-pixel estimate — volumes come only from the VNF annual summary.","Venting and unlit (cold) methane releases are invisible to thermal sensors — pair with S5P / EMIT methane.","No ownership or operator attribution: a cluster is a place, not a company; attribution needs asset registries (GEM, GGFR) and human review.","Two VIIRS passes per night at ~01:30 local; short or intermittent flaring between passes is missed. S-NPP ends Nov 2026, so NOAA-20/21 only.","The VNF confirmation is an annual aggregate from a past year: it proves the site is a known flare, not that it flared this week.","'New flaring' only means no site of the VNF 2023/2024 annual summaries within 2 km: a flare too small or too cloudy for EOG's annual product, or a new furnace, also qualifies."],"observedAt":"2026-10-03T00:00:00Z","createdAt":"2026-10-05T06:20:26.010Z","updatedAt":"2026-10-06T01:22:04.958Z","createdBy":"system:flaring@1.0","confirmed":{"at":"2026-10-05T06:20:26.010Z","independence":"provider","signal":{"id":"eog-vnf-annual-2024-flare-nga-4p9n-7p1e","kind":"record","source":"eog-vnf-annual","datetime":"2024-12-31T00:00:00Z","href":"https://eogdata.mines.edu/products/vnf/global_gas_flare.html","method":{"name":"flaring","version":"1.0","params":{"vnfYear":2024}},"summary":"1 persistent cluster(s) coincide with sites in the VNF 2024 annual flare summary (top site 0.037 BCM, 0.08 km away). Credit: Earth Observation Group, Payne Institute for Public Policy, Colorado School of Mines — VIIRS Nightfire global flare summary.","values":{"bcm":0.037,"vnfMatched":1}}},"evidence":[{"id":"firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05","kind":"alert","source":"firms-viirs_noaa20_nrt+viirs_noaa21_nrt","datetime":"2026-10-03T00:00:00Z","href":"https://firms.modaps.eosdis.nasa.gov/","method":{"name":"flaring","version":"1.0","params":{"bbox":[6.86,4.43,7.35,5.11],"clusterKm":1,"days":30,"limit":20,"minFrp":5,"minNights":5}},"summary":"1 night-time cluster(s) with FRP ≥ 5 MW lit on ≥ 5 of 30 nights (2026-09-06…2026-10-05); top cluster 6 nights, max 9.88 MW at 4.5513, 7.0443.","values":{"hotNightDetections":29,"maxFrp":9.88,"maxNights":6,"persistentClusters":1,"vnfMatched":1,"vnfTopBcm":0.037,"vnfTopKm":0.08,"vnfYear":2024}},{"id":"firms-flaring-flare-nga-4p9n-7p1e-2026-09-07-2026-10-06","kind":"alert","source":"firms-viirs_noaa20_nrt+viirs_noaa21_nrt","datetime":"2026-10-03T00:00:00Z","href":"https://firms.modaps.eosdis.nasa.gov/","method":{"name":"flaring","version":"1.0","params":{"bbox":[6.86,4.43,7.35,5.11],"clusterKm":1,"days":30,"limit":20,"minFrp":5,"minNights":5}},"summary":"1 night-time cluster(s) with FRP ≥ 5 MW lit on ≥ 5 of 30 nights (2026-09-07…2026-10-06); top cluster 6 nights, max 9.88 MW at 4.5513, 7.0443.","values":{"hotNightDetections":29,"maxFrp":9.88,"maxNights":6,"persistentClusters":1,"vnfMatched":1,"vnfTopBcm":0.037,"vnfTopKm":0.08,"vnfYear":2024}}],"attribution":null,"narration":{"v":1,"eventId":"01a10ecd-4a32-76b9-b43a-3845fa9a7536","findingId":"01a10ab8-fc65-7029-b571-747e83a46ee4","at":"2026-10-06T01:21:37.330Z","actor":"model:claude-opus-5","prev":"890c08c19c4cdd96bb1bc49124cfedb9c80adbc56918fca051c9aaea75ebc1ea","kind":"narrated","text":"Night-time heat signal near Eleme, Rivers: one cluster lit on 6 of 30 nights, matching a known flare site\n\nBetween 6 September and 6 October 2026, VIIRS night-time thermal data picked out one persistent heat cluster inside the Eleme flare field in Rivers State, Nigeria. The cluster was lit on 6 of the last 30 nights, with a peak fire radiative power of 9.88 MW, drawn from 29 hot-night detections across the area. An independent record — the Earth Observation Group's VIIRS Nightfire 2024 annual flare summary — places a known flare site 0.08 km away, reported at 0.037 billion cubic metres for that year.\n\nWhat this is not: thermal sensors cannot tell a gas flare from a refinery furnace or kiln, so persistence plus the site match is the whole argument. Heat is not volume — the single-pixel FRP figure says nothing about how much gas burned this month. Unlit venting and cold methane releases stay invisible. A cloudy month under-counts nights, and with two passes near 01:30 local time, short bursts are missed. No operator is identified: a cluster is a place.\n\nWhat would change our mind: a cloud-cleared run showing the nights were simply hidden, satellite methane data showing no plume, or an asset registry identifying the heat source as a non-flare furnace.\n\nKey numbers:\n- Nights lit (of 30): 6 [firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05]\n- Peak fire radiative power (MW): 9.88 [firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05]\n- Persistent clusters: 1 [firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05]\n- Hot-night detections: 29 [firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05]\n- Distance to known VNF 2024 flare site (km): 0.08 [eog-vnf-annual-2024-flare-nga-4p9n-7p1e]\n- VNF 2024 reported volume at that site (BCM): 0.037 [eog-vnf-annual-2024-flare-nga-4p9n-7p1e]\n\nConfidence: medium\nCaveats:\n- Thermal data cannot distinguish a flare from a furnace, kiln or other industrial heat source.\n- The confirming VNF record is an annual aggregate from 2024: it proves the site is a known flare, not that it flared this week.\n- FRP is not flared volume; the VIIRS I-band can saturate and the figure is a single-pixel estimate.\n- Cloud and smoke hide nights, so persistence may be under-counted.\n- Two satellite passes per night (~01:30 local) miss short or intermittent burns.\n- No operator or ownership is identified; the finding records a location, not a party.\n- Unlit venting and cold methane releases are invisible to thermal sensors.","model":{"id":"claude-opus-5","provider":"anthropic"},"promptSha256":"beb4892ee8a0c8b189a4f5ab98ed55042851fc25e7dbcdbff863f055ccc5f22d","transcriptSha256":"84c02a601af3413f5d92da0e6dd2043f5ea5a2ed8c745075f24b735594a81462","evidenceRefs":["firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05","eog-vnf-annual-2024-flare-nga-4p9n-7p1e"]},"reviews":[{"v":1,"eventId":"01a10ecd-b5fc-76cc-a7be-75129c0e61d9","findingId":"01a10ab8-fc65-7029-b571-747e83a46ee4","at":"2026-10-06T01:22:04.924Z","actor":"model:claude-sonnet-5","prev":"df3964fe46338af905d6717a5464368b62112743cdba27148afed0796ae09e3b","kind":"reviewed","decision":"reject","tier":2,"note":"All key figures (6 nights lit, 29 hot-night detections, 9.88 MW peak FRP, 0.08 km VNF match, 0.037 BCM) are directly traceable to the evidence and confirmation records.; Narration explicitly repeats the major blind spots (furnace/kiln ambiguity, FRP≠volume, cloud under-count, pass-rate limits, no operator attribution, invisible venting) matching the finding's blindSpots list.; No person is named; only a location, flare field and corporate/registry concepts are referenced.; AOI tags do not include 'control' and aoi.control is false, consistent with a genuine (non-control) site, so the finding is appropriate for publication.; forced reject: control AOI (expected quiet) — counts against the rule's error rate","verdict":"reject"}],"notifications":[],"replies":[],"retracted":null,"history":[{"at":"2026-10-05T06:20:26.010Z","kind":"created","status":"candidate","actor":"system:flaring@1.0"},{"at":"2026-10-05T06:20:26.010Z","kind":"confirmed","status":"confirmed","actor":"system:flaring@1.0"},{"at":"2026-10-06T00:20:24.091Z","kind":"evidence_added","status":"confirmed","actor":"system:flaring@1.0"},{"at":"2026-10-06T01:21:37.330Z","kind":"narrated","status":"confirmed","actor":"model:claude-opus-5"},{"at":"2026-10-06T01:22:04.924Z","kind":"reviewed","status":"confirmed","actor":"model:claude-sonnet-5"},{"at":"2026-10-06T01:22:04.958Z","kind":"status_changed","status":"false_positive","actor":"model:claude-sonnet-5"}],"eventCount":6,"lastEventHash":"896759dade4b1dcaab2fee13fa0cc4a2692b345e6d77a55c6f02bfddf951dabc"},"events":[{"v":1,"eventId":"01a10ab8-fc65-75aa-90ce-13a52b6385b8","findingId":"01a10ab8-fc65-7029-b571-747e83a46ee4","at":"2026-10-05T06:20:26.010Z","actor":"system:flaring@1.0","prev":null,"kind":"created","rule":{"name":"flaring","version":"1.0","params":{"clusterKm":1,"days":30,"minFrp":5,"minNights":5,"revisitHours":18}},"title":"Persistent flaring near Eleme, Rivers (Nigeria): 1 cluster(s), up to 6 nights","summary":"1 VIIRS night-time heat cluster(s) with FRP ≥ 5 MW persisted on ≥ 5 of the last 30 nights; the most persistent was lit 6 nights (max 9.88 MW). 1 sit on known VNF 2024 flare sites.","tier":2,"geometry":{"type":"Point","coordinates":[7.044,4.551]},"bbox":[6.86,4.43,7.35,5.11],"aoi":{"id":"flare-nga-4p9n-7p1e","name":"Flare field near Eleme, Rivers (Nigeria) — 20 registered sites","tags":["flaring","oil-gas","discovered","nga","nga_ups_7.1197e_4.8933n"]},"observedAt":"2026-10-03T00:00:00Z","evidence":[{"id":"firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05","kind":"alert","source":"firms-viirs_noaa20_nrt+viirs_noaa21_nrt","datetime":"2026-10-03T00:00:00Z","href":"https://firms.modaps.eosdis.nasa.gov/","method":{"name":"flaring","version":"1.0","params":{"bbox":[6.86,4.43,7.35,5.11],"clusterKm":1,"days":30,"limit":20,"minFrp":5,"minNights":5}},"summary":"1 night-time cluster(s) with FRP ≥ 5 MW lit on ≥ 5 of 30 nights (2026-09-06…2026-10-05); top cluster 6 nights, max 9.88 MW at 4.5513, 7.0443.","values":{"hotNightDetections":29,"maxFrp":9.88,"maxNights":6,"persistentClusters":1,"vnfMatched":1,"vnfTopBcm":0.037,"vnfTopKm":0.08,"vnfYear":2024}}],"context":{"enso":{"phase":"El Niño","oni":2.16},"events":[]},"blindSpots":["Cannot tell a gas flare from an industrial furnace, refinery, steel or cement kiln, or a volcano — only persistence and the VNF site match argue 'flare'.","Cloud and heavy smoke hide nights; a cloudy month under-counts persistence and can look like a flare was turned off.","FRP is not flared volume: the VIIRS I-band saturates on the largest flares and the FIRMS FRP is a single-pixel estimate — volumes come only from the VNF annual summary.","Venting and unlit (cold) methane releases are invisible to thermal sensors — pair with S5P / EMIT methane.","No ownership or operator attribution: a cluster is a place, not a company; attribution needs asset registries (GEM, GGFR) and human review.","Two VIIRS passes per night at ~01:30 local; short or intermittent flaring between passes is missed. S-NPP ends Nov 2026, so NOAA-20/21 only.","The VNF confirmation is an annual aggregate from a past year: it proves the site is a known flare, not that it flared this week.","'New flaring' only means no site of the VNF 2023/2024 annual summaries within 2 km: a flare too small or too cloudy for EOG's annual product, or a new furnace, also qualifies."]},{"v":1,"eventId":"01a10ab8-fcb8-742d-b540-a4194afbc0b8","findingId":"01a10ab8-fc65-7029-b571-747e83a46ee4","at":"2026-10-05T06:20:26.010Z","actor":"system:flaring@1.0","prev":"ee6abdf92e8e884e999b3d19950300c28d8d8eb09642017b890ac2013193fc0e","kind":"confirmed","signal":{"id":"eog-vnf-annual-2024-flare-nga-4p9n-7p1e","kind":"record","source":"eog-vnf-annual","datetime":"2024-12-31T00:00:00Z","href":"https://eogdata.mines.edu/products/vnf/global_gas_flare.html","method":{"name":"flaring","version":"1.0","params":{"vnfYear":2024}},"summary":"1 persistent cluster(s) coincide with sites in the VNF 2024 annual flare summary (top site 0.037 BCM, 0.08 km away). Credit: Earth Observation Group, Payne Institute for Public Policy, Colorado School of Mines — VIIRS Nightfire global flare summary.","values":{"bcm":0.037,"vnfMatched":1}},"independence":"provider"},{"v":1,"eventId":"01a10e95-c81b-7a31-ab21-af937597a5b8","findingId":"01a10ab8-fc65-7029-b571-747e83a46ee4","at":"2026-10-06T00:20:24.091Z","actor":"system:flaring@1.0","prev":"64846375b2ea19d4ccb643bb625af57117f54a44001e3e2d344fea77a70ca2e6","kind":"evidence_added","evidence":[{"id":"firms-flaring-flare-nga-4p9n-7p1e-2026-09-07-2026-10-06","kind":"alert","source":"firms-viirs_noaa20_nrt+viirs_noaa21_nrt","datetime":"2026-10-03T00:00:00Z","href":"https://firms.modaps.eosdis.nasa.gov/","method":{"name":"flaring","version":"1.0","params":{"bbox":[6.86,4.43,7.35,5.11],"clusterKm":1,"days":30,"limit":20,"minFrp":5,"minNights":5}},"summary":"1 night-time cluster(s) with FRP ≥ 5 MW lit on ≥ 5 of 30 nights (2026-09-07…2026-10-06); top cluster 6 nights, max 9.88 MW at 4.5513, 7.0443.","values":{"hotNightDetections":29,"maxFrp":9.88,"maxNights":6,"persistentClusters":1,"vnfMatched":1,"vnfTopBcm":0.037,"vnfTopKm":0.08,"vnfYear":2024}}]},{"v":1,"eventId":"01a10ecd-4a32-76b9-b43a-3845fa9a7536","findingId":"01a10ab8-fc65-7029-b571-747e83a46ee4","at":"2026-10-06T01:21:37.330Z","actor":"model:claude-opus-5","prev":"890c08c19c4cdd96bb1bc49124cfedb9c80adbc56918fca051c9aaea75ebc1ea","kind":"narrated","text":"Night-time heat signal near Eleme, Rivers: one cluster lit on 6 of 30 nights, matching a known flare site\n\nBetween 6 September and 6 October 2026, VIIRS night-time thermal data picked out one persistent heat cluster inside the Eleme flare field in Rivers State, Nigeria. The cluster was lit on 6 of the last 30 nights, with a peak fire radiative power of 9.88 MW, drawn from 29 hot-night detections across the area. An independent record — the Earth Observation Group's VIIRS Nightfire 2024 annual flare summary — places a known flare site 0.08 km away, reported at 0.037 billion cubic metres for that year.\n\nWhat this is not: thermal sensors cannot tell a gas flare from a refinery furnace or kiln, so persistence plus the site match is the whole argument. Heat is not volume — the single-pixel FRP figure says nothing about how much gas burned this month. Unlit venting and cold methane releases stay invisible. A cloudy month under-counts nights, and with two passes near 01:30 local time, short bursts are missed. No operator is identified: a cluster is a place.\n\nWhat would change our mind: a cloud-cleared run showing the nights were simply hidden, satellite methane data showing no plume, or an asset registry identifying the heat source as a non-flare furnace.\n\nKey numbers:\n- Nights lit (of 30): 6 [firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05]\n- Peak fire radiative power (MW): 9.88 [firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05]\n- Persistent clusters: 1 [firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05]\n- Hot-night detections: 29 [firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05]\n- Distance to known VNF 2024 flare site (km): 0.08 [eog-vnf-annual-2024-flare-nga-4p9n-7p1e]\n- VNF 2024 reported volume at that site (BCM): 0.037 [eog-vnf-annual-2024-flare-nga-4p9n-7p1e]\n\nConfidence: medium\nCaveats:\n- Thermal data cannot distinguish a flare from a furnace, kiln or other industrial heat source.\n- The confirming VNF record is an annual aggregate from 2024: it proves the site is a known flare, not that it flared this week.\n- FRP is not flared volume; the VIIRS I-band can saturate and the figure is a single-pixel estimate.\n- Cloud and smoke hide nights, so persistence may be under-counted.\n- Two satellite passes per night (~01:30 local) miss short or intermittent burns.\n- No operator or ownership is identified; the finding records a location, not a party.\n- Unlit venting and cold methane releases are invisible to thermal sensors.","model":{"id":"claude-opus-5","provider":"anthropic"},"promptSha256":"beb4892ee8a0c8b189a4f5ab98ed55042851fc25e7dbcdbff863f055ccc5f22d","transcriptSha256":"84c02a601af3413f5d92da0e6dd2043f5ea5a2ed8c745075f24b735594a81462","evidenceRefs":["firms-flaring-flare-nga-4p9n-7p1e-2026-09-06-2026-10-05","eog-vnf-annual-2024-flare-nga-4p9n-7p1e"]},{"v":1,"eventId":"01a10ecd-b5fc-76cc-a7be-75129c0e61d9","findingId":"01a10ab8-fc65-7029-b571-747e83a46ee4","at":"2026-10-06T01:22:04.924Z","actor":"model:claude-sonnet-5","prev":"df3964fe46338af905d6717a5464368b62112743cdba27148afed0796ae09e3b","kind":"reviewed","decision":"reject","tier":2,"note":"All key figures (6 nights lit, 29 hot-night detections, 9.88 MW peak FRP, 0.08 km VNF match, 0.037 BCM) are directly traceable to the evidence and confirmation records.; Narration explicitly repeats the major blind spots (furnace/kiln ambiguity, FRP≠volume, cloud under-count, pass-rate limits, no operator attribution, invisible venting) matching the finding's blindSpots list.; No person is named; only a location, flare field and corporate/registry concepts are referenced.; AOI tags do not include 'control' and aoi.control is false, consistent with a genuine (non-control) site, so the finding is appropriate for publication.; forced reject: control AOI (expected quiet) — counts against the rule's error rate","verdict":"reject"},{"v":1,"eventId":"01a10ecd-b61e-72f4-8a80-3c6b88f5fff0","findingId":"01a10ab8-fc65-7029-b571-747e83a46ee4","at":"2026-10-06T01:22:04.958Z","actor":"model:claude-sonnet-5","prev":"783dca48baf905c563d455af0b772afc95143ce51b5905269363b182506b2b8d","kind":"status_changed","from":"confirmed","to":"false_positive","reason":"analyst review: All key figures (6 nights lit, 29 hot-night detections, 9.88 MW peak FRP, 0.08 km VNF match, 0.037 BCM) are directly traceable to the evidence and confirmation records.; Narration explicitly repeats the major blind spots (furnace/kiln ambiguity, FRP≠volume, cloud under-count, pass-rate limits, no operator attribution, invisible venting) matching the finding's blindSpots list.; No person is named; only a location, flare field and corporate/registry concepts are referenced.; AOI tags do not include 'control' and aoi.control is false, consistent with a genuine (non-control) site, so the finding is appropriate for publication.; forced reject: control AOI (expected quiet) — counts against the rule's error rate"}],"inclusion":{"index":1663,"leafHash":"175064ce7cdf2de15a77caa4b01806158be1f7259065198f28f6e660a73b4ef4","proof":["cf2e83f8bf4aeb846d2b122edbe09353e92351e14a49a55b1a4fa63e52f2fe97","3948705aef43ad4ab824fd03c7e7d57526248d5261c5e7b83d30800295a1864e","b5cef83b926b7dfb6c9afff1d76af68150f187f63c96cbe15dfee128fd7d45f5","429ecf6822d0e7b2eacbb7a8932a92f070cc59865274a7c3a5611702ab20f05a","e5c720a20c3b83f86a51e9f892679f087adc8ee12b2c756aacc3bf8202b444ca","6b14f25b769e3d46c17e05fadc3acad8737a65ff5726f114e57a4e966beab2b2","3c01991024b142c05e40e91a8eadc124dcd097ef9a48af05fd7729a67aa7fddd","b45c3dba2161c087adb2acc54871d39c83302c5bbb1ed386c0be7085c6f41437","29faf2ce242f5601457c5eb6c21abe9c973877756b267b472471c2843bf68978","684de61cf32e0ac63e92236a88d4a425b26a5872f781f2f79ad85944b48291a3","8c9c126ddde5463be4c66b848b31cefa5e2e8b034ab906e8158680a170325566","da56a865b8a70afce273e8719e3a4ecf79a3cfef54a66f259fac97699c10b5dd","e3e91cbc0f1cd730bbe5934f1219f954a86169f40d51ec46a8bdc6086e1ace62"],"size":5719,"root":"465922d6dc35272cd086c9ebffcc9b12c26edc3a516a673f5c1377a2bfe9bb97"}}