{"finding":{"findingId":"01a0df7f-fd72-7ab0-a430-f8044527da2f","status":"false_positive","tier":2,"rule":{"name":"flaring","version":"1.0","params":{"clusterKm":1,"days":30,"minFrp":5,"minNights":5,"revisitHours":18}},"title":"Persistent flaring in Flare field DZA 35.81, -0.26 (7 VNF sites): 2 cluster(s), up to 8 nights","summary":"2 VIIRS night-time heat cluster(s) with FRP ≥ 5 MW persisted on ≥ 5 of the last 30 nights; the most persistent was lit 8 nights (max 17.4 MW). 2 sit on known VNF 2024 flare sites.","geometry":{"type":"Point","coordinates":[-0.256,35.808]},"bbox":[-0.44,35.7,-0.07,35.93],"aoi":{"id":"flare-dza-35p8n-0p3w","name":"Flare field DZA 35.81, -0.26 (7 VNF sites)","tags":["flaring","oil-gas","discovered","dza","dza_dng_0.2555w_35.8103n"]},"context":{"enso":{"phase":"El Niño","oni":1.8},"events":[]},"blindSpots":["Cannot tell a gas flare from an industrial furnace, refinery, steel or cement kiln, or a volcano — only persistence and the VNF site match argue 'flare'.","Cloud and heavy smoke hide nights; a cloudy month under-counts persistence and can look like a flare was turned off.","FRP is not flared volume: the VIIRS I-band saturates on the largest flares and the FIRMS FRP is a single-pixel estimate — volumes come only from the VNF annual summary.","Venting and unlit (cold) methane releases are invisible to thermal sensors — pair with S5P / EMIT methane.","No ownership or operator attribution: a cluster is a place, not a company; attribution needs asset registries (GEM, GGFR) and human review.","Two VIIRS passes per night at ~01:30 local; short or intermittent flaring between passes is missed. S-NPP ends Nov 2026, so NOAA-20/21 only.","The VNF confirmation is an annual aggregate from a past year: it proves the site is a known flare, not that it flared this week."],"observedAt":"2026-09-25T00:00:00Z","createdAt":"2026-09-26T20:54:22.777Z","updatedAt":"2026-09-26T21:25:44.296Z","createdBy":"system:flaring@1.0","confirmed":{"at":"2026-09-26T20:54:22.777Z","independence":"provider","signal":{"id":"eog-vnf-annual-2024-flare-dza-35p8n-0p3w","kind":"record","source":"eog-vnf-annual","datetime":"2024-12-31T00:00:00Z","href":"https://eogdata.mines.edu/products/vnf/global_gas_flare.html","method":{"name":"flaring","version":"1.0","params":{"vnfYear":2024}},"summary":"2 persistent cluster(s) coincide with sites in the VNF 2024 annual flare summary (top site 0.144 BCM, 0.27 km away). Credit: Earth Observation Group, Payne Institute for Public Policy, Colorado School of Mines — VIIRS Nightfire global flare summary.","values":{"bcm":0.144,"vnfMatched":2}}},"evidence":[{"id":"firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26","kind":"alert","source":"firms-viirs_noaa20_nrt+viirs_noaa21_nrt","datetime":"2026-09-25T00:00:00Z","href":"https://firms.modaps.eosdis.nasa.gov/","method":{"name":"flaring","version":"1.0","params":{"bbox":[-0.44,35.7,-0.07,35.93],"clusterKm":1,"days":30,"limit":20,"minFrp":5,"minNights":5}},"summary":"2 night-time cluster(s) with FRP ≥ 5 MW lit on ≥ 5 of 30 nights (2026-08-28…2026-09-26); top cluster 8 nights, max 17.4 MW at 35.8079, -0.2562.","values":{"hotNightDetections":43,"maxFrp":18.6,"maxNights":8,"persistentClusters":2,"vnfMatched":2,"vnfTopBcm":0.144,"vnfTopKm":0.27,"vnfYear":2024}}],"attribution":null,"narration":{"v":1,"eventId":"01a0df9b-b981-792d-96fa-660abf79731f","findingId":"01a0df7f-fd72-7ab0-a430-f8044527da2f","at":"2026-09-26T21:25:19.873Z","actor":"model:claude-opus-5","prev":"951b99d19e2132c5bf1c8e5e716b300f7cf71099e2959415a2b062dde719d3dd","kind":"narrated","text":"Algerian flare field lights up on 8 of 30 nights — two persistent heat clusters match known 2024 flare sites\n\nNight-time satellite passes over the flare field at roughly 35.81N, -0.26 (Algeria) picked up 2 clusters of heat that were lit on at least 5 of the last 30 nights (2026-08-28 to 2026-09-26). The most persistent burned on 8 separate nights, peaking at 17.4 MW at 35.8079, -0.2562; across the area there were 43 hot-night detections, the brightest at 18.6 MW. Independently, 2 of these clusters fall on sites listed in the Earth Observation Group's VIIRS Nightfire 2024 annual flare summary, the top one 0.27 km away and credited with 0.144 billion cubic metres that year. What this is not: thermal sensors cannot separate a gas flare from a refinery furnace, a steel or cement kiln, or other industrial heat, and the VNF match proves the site is a known flare location in a past year, not what burned this month. It is not a volume measurement — brightness is not flared gas. It says nothing about who operates the site. Cold venting and unlit methane are invisible here. Our view would change with clear-sky nights showing no heat, methane sounding from S5P or EMIT, or asset records placing a non-flare industrial plant at these coordinates.\n\nKey numbers:\n- Persistent night-time heat clusters: 2 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Nights lit, most persistent cluster: 8 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Peak fire radiative power, top cluster (MW): 17.4 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Brightest detection in area (MW): 18.6 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Hot-night detections in 30 days: 43 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Clusters matching VNF 2024 flare sites: 2 [eog-vnf-annual-2024-flare-dza-35p8n-0p3w]\n- VNF 2024 top-site flared volume (BCM): 0.144 [eog-vnf-annual-2024-flare-dza-35p8n-0p3w]\n\nConfidence: high\nCaveats:\n- Thermal data cannot distinguish a flare from a furnace, refinery or kiln; persistence plus the VNF site match is the only argument for 'flare'.\n- Cloud or smoke hides nights, so a cloudy month under-counts persistence and can mimic a shut-in flare.\n- FRP is a single-pixel brightness estimate that saturates on large flares; it is not a measure of gas volume.\n- The confirming VNF record is an annual aggregate from 2024 — it shows a known flare site, not this month's activity.\n- Only two overpasses per night (~01:30 local, NOAA-20/21); short or intermittent flaring between passes is missed.\n- No operator or ownership attribution: a cluster is a place, not a company.","model":{"id":"claude-opus-5","provider":"anthropic"},"promptSha256":"fd6410cb1b2c7ca92c44b92537ed13f81857b3292e5cbe522c0fa051ab18f52b","transcriptSha256":"7e7d97044bc1467f0eb66f6008431f0b50c762fc46c355a229dec0b84ccd6b22","evidenceRefs":["firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26","eog-vnf-annual-2024-flare-dza-35p8n-0p3w"]},"reviews":[{"v":1,"eventId":"01a0df9c-18e4-7d8a-a6b9-6688ee6406f6","findingId":"01a0df7f-fd72-7ab0-a430-f8044527da2f","at":"2026-09-26T21:25:44.292Z","actor":"model:claude-sonnet-5","prev":"e4a8466bac4fc54efd9a652191fcd217adc1cf3f4dc68c7816c6c45e763eb436","kind":"reviewed","decision":"reject","tier":2,"note":"All numeric claims (2 clusters, 8 nights, 17.4 MW peak, 18.6 MW brightest, 43 hot-night detections, 2 VNF matches, 0.144 BCM) match the evidence values exactly.; Narration explicitly reproduces the key blind spots: cannot distinguish flare from furnace/kiln, cloud under-counting, FRP saturation vs volume, annual VNF aggregate limits, revisit-gap misses, no operator attribution, and cold venting invisibility.; No natural person is named; only a site location and operator-agnostic language is used.; AOI is tagged as a real discovered flare field (control: false, no 'control' tag), so it is appropriate for public reporting.; forced reject: control AOI (expected quiet) — counts against the rule's error rate","verdict":"reject"}],"notifications":[],"replies":[],"retracted":null,"history":[{"at":"2026-09-26T20:54:22.777Z","kind":"created","status":"candidate","actor":"system:flaring@1.0"},{"at":"2026-09-26T20:54:22.777Z","kind":"confirmed","status":"confirmed","actor":"system:flaring@1.0"},{"at":"2026-09-26T21:25:19.873Z","kind":"narrated","status":"confirmed","actor":"model:claude-opus-5"},{"at":"2026-09-26T21:25:44.292Z","kind":"reviewed","status":"confirmed","actor":"model:claude-sonnet-5"},{"at":"2026-09-26T21:25:44.296Z","kind":"status_changed","status":"false_positive","actor":"model:claude-sonnet-5"}],"eventCount":5,"lastEventHash":"4e6f9351d989001f0f4906119235088e84dd3d152e922f783c8a38df2f7cb81b"},"events":[{"v":1,"eventId":"01a0df7f-fd72-793b-8cf8-18ab7324169f","findingId":"01a0df7f-fd72-7ab0-a430-f8044527da2f","at":"2026-09-26T20:54:22.777Z","actor":"system:flaring@1.0","prev":null,"kind":"created","rule":{"name":"flaring","version":"1.0","params":{"clusterKm":1,"days":30,"minFrp":5,"minNights":5,"revisitHours":18}},"title":"Persistent flaring in Flare field DZA 35.81, -0.26 (7 VNF sites): 2 cluster(s), up to 8 nights","summary":"2 VIIRS night-time heat cluster(s) with FRP ≥ 5 MW persisted on ≥ 5 of the last 30 nights; the most persistent was lit 8 nights (max 17.4 MW). 2 sit on known VNF 2024 flare sites.","tier":2,"geometry":{"type":"Point","coordinates":[-0.256,35.808]},"bbox":[-0.44,35.7,-0.07,35.93],"aoi":{"id":"flare-dza-35p8n-0p3w","name":"Flare field DZA 35.81, -0.26 (7 VNF sites)","tags":["flaring","oil-gas","discovered","dza","dza_dng_0.2555w_35.8103n"]},"observedAt":"2026-09-25T00:00:00Z","evidence":[{"id":"firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26","kind":"alert","source":"firms-viirs_noaa20_nrt+viirs_noaa21_nrt","datetime":"2026-09-25T00:00:00Z","href":"https://firms.modaps.eosdis.nasa.gov/","method":{"name":"flaring","version":"1.0","params":{"bbox":[-0.44,35.7,-0.07,35.93],"clusterKm":1,"days":30,"limit":20,"minFrp":5,"minNights":5}},"summary":"2 night-time cluster(s) with FRP ≥ 5 MW lit on ≥ 5 of 30 nights (2026-08-28…2026-09-26); top cluster 8 nights, max 17.4 MW at 35.8079, -0.2562.","values":{"hotNightDetections":43,"maxFrp":18.6,"maxNights":8,"persistentClusters":2,"vnfMatched":2,"vnfTopBcm":0.144,"vnfTopKm":0.27,"vnfYear":2024}}],"context":{"enso":{"phase":"El Niño","oni":1.8},"events":[]},"blindSpots":["Cannot tell a gas flare from an industrial furnace, refinery, steel or cement kiln, or a volcano — only persistence and the VNF site match argue 'flare'.","Cloud and heavy smoke hide nights; a cloudy month under-counts persistence and can look like a flare was turned off.","FRP is not flared volume: the VIIRS I-band saturates on the largest flares and the FIRMS FRP is a single-pixel estimate — volumes come only from the VNF annual summary.","Venting and unlit (cold) methane releases are invisible to thermal sensors — pair with S5P / EMIT methane.","No ownership or operator attribution: a cluster is a place, not a company; attribution needs asset registries (GEM, GGFR) and human review.","Two VIIRS passes per night at ~01:30 local; short or intermittent flaring between passes is missed. S-NPP ends Nov 2026, so NOAA-20/21 only.","The VNF confirmation is an annual aggregate from a past year: it proves the site is a known flare, not that it flared this week."]},{"v":1,"eventId":"01a0df7f-fd75-755b-b40c-466d57fccf6c","findingId":"01a0df7f-fd72-7ab0-a430-f8044527da2f","at":"2026-09-26T20:54:22.777Z","actor":"system:flaring@1.0","prev":"9720e8271e8cbcb37ea589992b8ca81a8862da387762508c30351eb21c59f726","kind":"confirmed","signal":{"id":"eog-vnf-annual-2024-flare-dza-35p8n-0p3w","kind":"record","source":"eog-vnf-annual","datetime":"2024-12-31T00:00:00Z","href":"https://eogdata.mines.edu/products/vnf/global_gas_flare.html","method":{"name":"flaring","version":"1.0","params":{"vnfYear":2024}},"summary":"2 persistent cluster(s) coincide with sites in the VNF 2024 annual flare summary (top site 0.144 BCM, 0.27 km away). Credit: Earth Observation Group, Payne Institute for Public Policy, Colorado School of Mines — VIIRS Nightfire global flare summary.","values":{"bcm":0.144,"vnfMatched":2}},"independence":"provider"},{"v":1,"eventId":"01a0df9b-b981-792d-96fa-660abf79731f","findingId":"01a0df7f-fd72-7ab0-a430-f8044527da2f","at":"2026-09-26T21:25:19.873Z","actor":"model:claude-opus-5","prev":"951b99d19e2132c5bf1c8e5e716b300f7cf71099e2959415a2b062dde719d3dd","kind":"narrated","text":"Algerian flare field lights up on 8 of 30 nights — two persistent heat clusters match known 2024 flare sites\n\nNight-time satellite passes over the flare field at roughly 35.81N, -0.26 (Algeria) picked up 2 clusters of heat that were lit on at least 5 of the last 30 nights (2026-08-28 to 2026-09-26). The most persistent burned on 8 separate nights, peaking at 17.4 MW at 35.8079, -0.2562; across the area there were 43 hot-night detections, the brightest at 18.6 MW. Independently, 2 of these clusters fall on sites listed in the Earth Observation Group's VIIRS Nightfire 2024 annual flare summary, the top one 0.27 km away and credited with 0.144 billion cubic metres that year. What this is not: thermal sensors cannot separate a gas flare from a refinery furnace, a steel or cement kiln, or other industrial heat, and the VNF match proves the site is a known flare location in a past year, not what burned this month. It is not a volume measurement — brightness is not flared gas. It says nothing about who operates the site. Cold venting and unlit methane are invisible here. Our view would change with clear-sky nights showing no heat, methane sounding from S5P or EMIT, or asset records placing a non-flare industrial plant at these coordinates.\n\nKey numbers:\n- Persistent night-time heat clusters: 2 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Nights lit, most persistent cluster: 8 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Peak fire radiative power, top cluster (MW): 17.4 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Brightest detection in area (MW): 18.6 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Hot-night detections in 30 days: 43 [firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26]\n- Clusters matching VNF 2024 flare sites: 2 [eog-vnf-annual-2024-flare-dza-35p8n-0p3w]\n- VNF 2024 top-site flared volume (BCM): 0.144 [eog-vnf-annual-2024-flare-dza-35p8n-0p3w]\n\nConfidence: high\nCaveats:\n- Thermal data cannot distinguish a flare from a furnace, refinery or kiln; persistence plus the VNF site match is the only argument for 'flare'.\n- Cloud or smoke hides nights, so a cloudy month under-counts persistence and can mimic a shut-in flare.\n- FRP is a single-pixel brightness estimate that saturates on large flares; it is not a measure of gas volume.\n- The confirming VNF record is an annual aggregate from 2024 — it shows a known flare site, not this month's activity.\n- Only two overpasses per night (~01:30 local, NOAA-20/21); short or intermittent flaring between passes is missed.\n- No operator or ownership attribution: a cluster is a place, not a company.","model":{"id":"claude-opus-5","provider":"anthropic"},"promptSha256":"fd6410cb1b2c7ca92c44b92537ed13f81857b3292e5cbe522c0fa051ab18f52b","transcriptSha256":"7e7d97044bc1467f0eb66f6008431f0b50c762fc46c355a229dec0b84ccd6b22","evidenceRefs":["firms-flaring-flare-dza-35p8n-0p3w-2026-08-28-2026-09-26","eog-vnf-annual-2024-flare-dza-35p8n-0p3w"]},{"v":1,"eventId":"01a0df9c-18e4-7d8a-a6b9-6688ee6406f6","findingId":"01a0df7f-fd72-7ab0-a430-f8044527da2f","at":"2026-09-26T21:25:44.292Z","actor":"model:claude-sonnet-5","prev":"e4a8466bac4fc54efd9a652191fcd217adc1cf3f4dc68c7816c6c45e763eb436","kind":"reviewed","decision":"reject","tier":2,"note":"All numeric claims (2 clusters, 8 nights, 17.4 MW peak, 18.6 MW brightest, 43 hot-night detections, 2 VNF matches, 0.144 BCM) match the evidence values exactly.; Narration explicitly reproduces the key blind spots: cannot distinguish flare from furnace/kiln, cloud under-counting, FRP saturation vs volume, annual VNF aggregate limits, revisit-gap misses, no operator attribution, and cold venting invisibility.; No natural person is named; only a site location and operator-agnostic language is used.; AOI is tagged as a real discovered flare field (control: false, no 'control' tag), so it is appropriate for public reporting.; forced reject: control AOI (expected quiet) — counts against the rule's error rate","verdict":"reject"},{"v":1,"eventId":"01a0df9c-18e7-7115-869f-f6ef0fde93b0","findingId":"01a0df7f-fd72-7ab0-a430-f8044527da2f","at":"2026-09-26T21:25:44.296Z","actor":"model:claude-sonnet-5","prev":"c9c3d7b7cca9afedee63196bd6e6c5c2ebf1da873169397e65db5902a00475b0","kind":"status_changed","from":"confirmed","to":"false_positive","reason":"analyst review: All numeric claims (2 clusters, 8 nights, 17.4 MW peak, 18.6 MW brightest, 43 hot-night detections, 2 VNF matches, 0.144 BCM) match the evidence values exactly.; Narration explicitly reproduces the key blind spots: cannot distinguish flare from furnace/kiln, cloud under-counting, FRP saturation vs volume, annual VNF aggregate limits, revisit-gap misses, no operator attribution, and cold venting invisibility.; No natural person is named; only a site location and operator-agnostic language is used.; AOI is tagged as a real discovered flare field (control: false, no 'control' tag), so it is appropriate for public reporting.; forced reject: control AOI (expected quiet) — counts against the rule's error rate"}],"inclusion":{"index":163,"leafHash":"dc3b86d8cab8bce8b0cd9448bafdc3afc848da1825fd12623c52d8384ef04660","proof":["c073e9f1c0b9dc37463280aefe6fd1a7254be72562f2557d5a5686d79e4f188a","bc3c7c076f3e33dcda607f0cbef59548cd4850e609c7bc7f0edc104082dad94b","4a794c60066bcc31523b0086e7df9dbedca33e5ed9ed356404f06eb8db1ab955","2ffddeb73a773a59032e7b1db79aed14a6ff02c4cec3e5e67194c75592b0a61c","13be133a602d7e310ef2f294fd6724facf9e1a5990f4feb970feac0f4838603b","0fcf67955c0d83e3763f4cb1e1535a26d56fbd1960df3611140cb83239d78ebc","d15097d7e4efdc6a96a8e68bb14d57adfdc9b7c1eab701d233413dfd8ce434d4","1e6b35b77ca24da32136c1f20f9724e4c9e881569d9550e8b5024cf584b97d34","724fa399933aebb8c2eaf4f8fea128daa30ce5da85d4ed04b4c9d4e3e8b8d4ca","bd3a8a79a52294dac12ac22a4f40b4c58fe95cb4b16ab97a096fb79fbb659f33","73393b17fa13abd55acac6cf12debab3c24d87421493361dbf7f0d8b02522777","da56a865b8a70afce273e8719e3a4ecf79a3cfef54a66f259fac97699c10b5dd","e3e91cbc0f1cd730bbe5934f1219f954a86169f40d51ec46a8bdc6086e1ace62"],"size":5719,"root":"465922d6dc35272cd086c9ebffcc9b12c26edc3a516a673f5c1377a2bfe9bb97"}}